Name |
Value |
---|
Supply voltages |
|
- Electronic supply voltage Ue*2 |
18..30 V |
- Electronic current consumption@ Ue=24V*3 |
typ. 45 mA |
- Power supply voltage Up*4 |
9..60 V |
|
|
Output current |
|
- Max. output current |
80 A |
- Continuous output current (certified UL)*5 @Up ≤ 24V
@Up ≤ 60V |
14.5 A
12.2 A |
- Continuous output current (not certified)*6 @Up ≤ 24V
@Up ≤ 48V |
16 A
13 A |
|
|
PWM |
|
- Output voltage |
90% Up |
- PWM frequency |
25, 32*7, 50 kHz |
- PWM mode |
symmetrical / asymmetrical |
|
|
Motor types |
|
- DC motors |
yes |
- BLDC motors |
yes |
- Linear motors |
yes |
- Stepper motors |
no |
|
|
Mechanical |
|
- Size LxWxH |
70 x 50 x 13 mm |
|
|
CAN bus |
|
- Protocol |
DS301 |
- Device profile |
DS402 |
- Galvanically isolated |
no |
|
|
Sensor supply (Hall) |
|
- Output voltage |
5 V |
- Max. output current |
0.05 A |
|
|
Sensor supply (Encoder) |
|
- Output voltage |
5 V |
- Max. output current |
0.2 A |
|
|
Encoder |
|
- Type |
sin / cos |
- Input voltage |
1 V peak-peak, differential |
- Signal type |
sine/cosine, analog, differential |
|
|
Hall sensors |
|
- Input voltage |
0..5 V |
- Signal type |
open collector, single ended |
|
|
Digital inputs |
|
- Number - digital inputs |
8 (Din0..7) |
|
|
Digital outputs |
|
- Number |
3 (Dout0..2) |
- Continuous output current (certified UL) |
1 A |
- Continuous output current (not certified) |
1.5 A |
- Load Dout0..1 |
resistive, low inductive |
- Load Dout2 |
resistive, inductive |
|
|
Analog inputs |
|
- Number |
1 (Ain0) |
- Signal type - Ain |
+/- 10 V, 12 Bit, differential |
|
|
Modifications and errors excepted.
*1 The certified performance data must be observed (see UL Instruction Note)
*2 No reverse polarity protection, the destruction limit is at overvoltage of >= 33V or short-term peak voltage of 37V < 1s
*3 power amplifier switched off, 5V output (sensor supply) is free
*4 No reverse polarity protection, the destruction limit is at overvoltage of >= 80V
*5 connector cable with max. possible cable cross-section, PWM frequency 32 kHz (asymmetrical), ambient temperature 40 °C, I/O's and 5V output active, RMS current: 14.5 A → 12 Aeff, 12.2 A → 10 Aeff
*6 connector cable with max. possible cable cross-section, PWM frequency 32 kHz (asymmetrical), ambient temperature 40 °C, I/O's and 5V output free, RMS current: 16 A → 13 Aeff, 13 A → 10.6 Aeff
no guarantee, since value is determined empirical, please consider the application notes to determine the continuous current
*7 default value